Resultados 1 - 20 de 790
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38581573

RESUMO

PURPOSE: Dysphagia is a prevalent symptom observed in acute stroke. Several bedside screening tests are employed for the early detection of dysphagia. Pulse oximetry emerges as a practical and supportive method to augment the existing techniques utilized during bedside swallowing assessments. Desaturation levels, as measured by pulse oximetry, are acknowledged as indicative of aspiration by certain screening tests. However, the predictive capability of pulse oximetry in determining aspiration remains a subject of controversy. The objective of this study was to compare aspiration and oxygen desaturation levels by time and aspiration severity in dysphagic patients compared to healthy controls. It also aimed to evaluate the accuracy of pulse oximetry by comparing it with VFSS findings in detecting aspiration in both liquid (IDDSI-0) and semi-solid (IDDSI-4) consistencies. MATERIALS AND METHODS: Eighty subjects (40 healthy and 40 acute stroke patients) participated. Patients suspected of dysphagia underwent videofluoroscopy as part of the stroke unit's routine procedure. Baseline SpO2 was measured before VFSS, and stabilized values were recorded. Sequential IDDSI-0 and IDDSI-4 barium tests were conducted with 5 ml boluses. Stabilized SPO2 values were recorded during swallowing and 3-min post-feeding. Patients with non-dysphagia received equal bolus monitoring. Changes in SPO2 during, before, and after swallowing were analyzed for each consistency in both groups. RESULTS: The study revealed a statistically significant difference in SPO2 between patients with dysphagia and controls for IDDSI-4 and IDSSI-0. In IDDSI-4, 20% of patients experienced SpO2 decrease compared to 2.5% in control group (p = 0.013). For IDDSI-0, 35% of patients showed SpO2 decrease, while none in the control group did (p = 0.0001). Aspiration rates were 2.5% in IDDSI-4 and 57.5% in IDDSI-0. In IDDSI-0, SpO2 decrease significantly correlated with aspiration (p = 0.0001). In IDDSI-4, 20.5% had SpO2 decrease without aspiration, and showing no significant difference (p = 0.613). Penetration-Aspiration Scale scores had no significant association with SpO2 decrease (p = 0.602). Pulse oximetry in IDDSI-4 had limited sensitivity (0%) and positive predictive value, (0%) while in IDDSI-0, it demonstrated acceptable sensitivity (60.9%) and specificity (100%) with good discrimination capability (AUC = 0.83). CONCLUSIONS: A decrease in SPO2 may indicate potential aspiration but is insufficient alone for detection. This study proposes pulse oximetry as a valuable complementary tool in assessing dysphagia but emphasizes that aspiration cannot be reliably predicted based solely on SpO2 decrease.

2.
J Clin Sleep Med ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38652502

RESUMO

STUDY OBJECTIVES: To evaluate the accuracy and precision of continuous overnight oxygen saturation (SpO2) measurement by a commercial wrist device (WD) incorporating high-grade sensors, and investigate WD estimation of sleep-disordered breathing by quantifying overnight oxygen desaturation index (ODI) compared to polysomnography (PSG) ODI and apnea-hypopnea index (AHI) with and without sleep questionnaire data, to assess WD ability to detect obstructive sleep apnea (OSA) and determine its severity. METHODS: Participants completed sleep questionnaires, had a WD (Samsung Galaxy Watch 4) placed on their wrist, and underwent attending, in-lab overnight PSG (Nihon Kohden) with pulse oximetry probe secured either to a finger or ear lobe. PSG data was scored by a single experienced registered PSG technologist. Statistical analysis included demographic characteristics, continuous SpO2 measurement WD vs PSG root mean square error (RMSE) with Bland Altman plot and linear regression associations. Predictive models for PSG ODI and AHI severity were built using logistic regression with probability cutoffs determined via receiver operating curve (ROC) characteristics. RESULTS: The 51 participants analyzed had median age of 49 (range 22-78) years, 66.7% were male, with median body mass index (BMI) 28.1 (range 20.1, 47.3) kg/m2 with race/ethnicity distribution of 49.0% Caucasian, 25.5% Hispanic, 9.8% African-American, 9.8% Asian, and 5.9% Middle Eastern. WD vs PSG continuous SpO2 measurement in percentage points demonstrated bias of 0.91 (CI95 0.38, 1.45), standard deviation 2.37 (CI95 2.36, 2.38), and RMSE 2.54 (CI95 2.34, 2.73). WD area under the curve (AUC) ROC characteristics for predicting PSG were 0.882 ODI>15/h, 0.894 AHI>30/h, 0.800 AHI>15/h, and 0.803 AHI>5/h. WD plus select sleep questionnaire AUCs for predicting PSG were 0.943 AHI>30/h, 0.868 AHI>15/h, and 0.863 AHI>5/h. CONCLUSIONS: The WD conducted reliable overnight continuous SpO2 monitoring with RMSE <3% vs PSG. Predictive models of PSG AHI based on WD measurements alone, or plus sleep questionnaires, demonstrated excellent to outstanding discrimination for OSA identification and severity. Longitudinal WD use should be evaluated promptly based on WD potential to improve accessibility and accuracy of OSA testing, as well as support treatment follow-up.

3.
medRxiv ; 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38585762

RESUMO

Background: Recent studies showed that Black patients more often have falsely normal oxygen saturation on pulse oximetry compared to White patients. However, whether the racial differences in occult hypoxemia are mediated by other clinical differences is unknown. Methods: We conducted a retrospective case-control study utilizing two large ICU databases (eICU and MIMIC-IV). We defined occult hypoxemia as oxygen saturation on pulse oximetry within 92-98% despite oxygen saturation on arterial blood gas below 90%. We assessed associations of commonly measured clinical factors with occult hypoxemia using multivariable logistic regression and conducted mediation analysis of the racial effect. Results: Among 24,641 patients, there were 1,855 occult hypoxemia cases and 23,786 controls. In both datasets, Black patients were more likely to have occult hypoxemia (unadjusted odds ratio 1.66 [95%-CI: 1.41-1.95] in eICU and 2.00 [95%-CI: 1.22-3.14] in MIMIC-IV). In multivariable models, higher respiratory rate, PaCO2 and creatinine as well as lower hemoglobin were associated with increased odds of occult hypoxemia. Differences in the commonly measured clinical markers accounted for 9.2% and 44.4% of the racial effect on occult hypoxemia in eICU and MIMIC-IV, respectively. Conclusion: Clinical differences, in addition to skin tone, might mediate some of the racial differences in occult hypoxemia.

4.
Eur J Pediatr ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38592485

RESUMO

The aim of this study was to analyze signal loss (SL) resulting from low signal quality of pulse oximetry-derived hemoglobin oxygen saturation (SpO2) measurements during prolonged hypoxemic episodes (pHE) in very preterm infants receiving automatic oxygen control (AOC). We did a post hoc analysis of a randomized crossover study of AOC, programmed to set FiO2 to "back-up FiO2" during SL. In 24 preterm infants (median (interquartile range)) gestational age 25.3 (24.6 to 25.6) weeks, recording time 12.7 h (12.2 to 13.6 h) per infant, we identified 76 pHEs (median duration 119 s (86 to 180 s)). In 50 (66%) pHEs, SL occurred for a median duration of 51 s (33 to 85 s) and at a median frequency of 2 (1 to 2) SL-periods per pHE. SpO2 before and after SL was similar (82% (76 to 88%) vs 82% (76 to 87%), p = 0.3)).  Conclusion: SL is common during pHE and must hence be considered in AOC-algorithm designs. Administering a "backup FiO2" (which reflects FiO2-requirements during normoxemia) during SL may prolong pHE with SL.  Trial registration: The study was registered at www. CLINICALTRIALS: gov under the registration no. NCT03785899. WHAT IS KNOWN: • Previous studies examined SpO2 signal loss (SL) during routine manual oxygen control being rare, but pronounced in lower SpO2 states. • Oxygen titration during SL is unlikely to be beneficial as SpO2 may recover to a normoxic range. WHAT IS NEW: • Periods of low signal quality of SpO2 are common during pHEs and while supported with automated oxygen control (SPOC), FiO2 is set to a back-up value reflecting FiO2 requirements during normoxemia in response to SL, although SpO2 remained below target until signal recovery. • FiO2 overshoots following pHEs were rare during AOC and occurred with a delayed onset; therefore, increased FiO2 during SL does not necessarily lead to overshoots.

6.
Br J Anaesth ; 132(5): 957-963, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38443287

RESUMO

BACKGROUND: Pulse oximetry uses noninvasive optical measurements of light transmission from each of two sources through vascularised living tissue over the cardiac cycle (SpO2). From those measurements, the relative amount of oxygenated haemoglobin (SaO2) in circulating blood can be deduced. Recent reports have shown that, compared with SaO2 measurements from blood samples, SpO2 measurements are biased erroneously high for patients with dark skin. METHODS: We developed a new method, spectrally resolved photoplethysmography (srPPG), to examine how spectral bandwidth affects the transmission of polychromatic light through the fingertip across the cardiac cycle. We measured and recorded the spectral transmission through the fingertip as the O2 concentration in inspired air was reduced. We applied digital spectral filters of two different bandwidths, narrow or broad, to the same srPPG recordings to determine whether SpO2 readings systematically varied for the two bandwidths. The srPPG method also allowed us to measure the fractional amount of melanin in the optical path. The effect of melanin content on the ratio of SpO2 readings for narrow and broad spectral bandwidths was analysed. RESULTS: We hypothesised, based upon the Beer-Lambert law, and then showed experimentally, that the light emission spectra of light-emitting diode light sources, as used in commercial pulse oximeters, result in erroneously high SpO2 measurements for patients having greater melanin concentrations in their skin than those of the subject pool used for instrument calibration. CONCLUSIONS: To eliminate melanin bias, pulse oximeters should use much narrower spectral bandwidths than those used in current models.


Assuntos
Melaninas , Oximetria , Humanos , Oxigênio , Oxiemoglobinas , Calibragem
7.
J Clin Monit Comput ; 2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38460103

RESUMO

Large data sets from electronic health records (EHR) have been used in journal articles to demonstrate race-based imprecision in pulse oximetry (SpO2) measurements. These articles do not appear to recognize the impact of the variability of the SpO2 values with respect to time ("deviation time"). This manuscript seeks to demonstrate that due to this variability, EHR data should not be used to quantify SpO2 error. Using the MIMIC-IV Waveform dataset, SpO2 values are sampled from 198 patients admitted to an intensive care unit and used as reference samples. The error derived from the EHR data is simulated using a set of deviation times. The laboratory oxygen saturation measurements are also simulated such that the performance of three simulated pulse oximeter devices will produce an average root mean squared (ARMS) error of 2%. An analysis is then undertaken to reproduce a medical device submission to a regulatory body by quantifying the mean error, the standard deviation of the error, and the ARMS error. Bland-Altman plots were also generated with their Limits of Agreements. Each analysis was repeated to evaluate whether the measurement errors were affected by increasing the deviation time. All error values increased linearly with respect to the logarithm of the time deviation. At 10 min, the ARMS error increased from a baseline of 2% to over 4%. EHR data cannot be reliably used to quantify SpO2 error. Caution should be used in interpreting prior manuscripts that rely on EHR data.

8.
Sleep Breath ; 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38504043

RESUMO

PURPOSE: Obstructive sleep apnoea (OSA) is common, yet often undiagnosed. Self-administered, overnight pulse oximetry (OPO) could screen for OSA in asymptomatic, older populations. However, the inter-night variability of OPO in an asymptomatic, older population is unknown. We determined the inter-night variability of home OPO parameters in an older population and correlated with sleep questionnaires. METHODS: Participants > 50 years without a diagnosis of OSA undertook home OPO for three consecutive nights and completed two sleep questionnaires (STOP-BANG (SBQ) and Epworth Sleepiness Score (ESS)). Analysis was performed with linear mixed models and Spearman's correlation coefficient. RESULTS: There was no difference in oxygen desaturation index (ODI), MeanSpO2, MinimumSpO2, and time spent with SpO2 < 90% (T90) across two or three nights (P ≥ 0.282). However, the variability of all parameters across nights increased with the magnitude of departure from normal values (P ≤ 0.002). All OPO parameters were associated with age (P ≤ 0.034) and body mass index (P ≤ 0.049). There was a weak correlation between three OPO parameters and SBQ (absolute ρ = 0.22 to 0.32; P ≤ 0.021), but not ESS (P ≥ 0.254). CONCLUSION: Inter-night variability of home OPO was minimal when values were near-normal in an older population. However, as values depart from normal, the inter-night variability increases, indicating the need for multiple night recordings. Low correlation to sleep questionnaires suggest the need for more robust OSA questionnaires in an asymptomatic population.

9.
Cardiol Young ; : 1-6, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38469722

RESUMO

OBJECTIVES: Monitoring venous saturation allows identification of inadequate systemic oxygen delivery. The aim was to develop a model using non-invasive haemodynamic variables to estimate the inferior caval vein saturation and to determine its prognostic utility. METHODS: This is a single-centre, retrospective study. A Bayesian Pearson's correlation was conducted to model the inferior caval vein saturation. Next, a Bayesian linear regression was conducted for data from all the patients and from only those with parallel circulation. Venous saturation estimations were developed. The correlation of these estimates to the actual inferior caval vein saturation was assessed. The resulting models were then applied to two validation cohorts: biventricular circulation (arterial switch operation) and parallel circulation (Norwood operation). RESULTS: One hundred and thirteen datasets were collected across 15 patients. Of which, 65% had parallel circulation. In all patients, the measured and estimated inferior caval vein saturations had a moderate and significant correlation with a coefficient of 0.64. In patients with parallel circulation, the measured and estimated inferior caval vein saturation had a moderate and significant correlation with a coefficient of 0.61. In the biventricular circulation cohort, the estimated inferior caval vein saturation had an area under the curve of 0.71 with an optimal cut-off of 49. In the parallel circulation cohort, the estimated interior caval vein saturation had an area under the curve of 0.83 with an optimal cut-off of 24%. CONCLUSION: The inferior caval vein saturation can be estimated utilising non-invasive haemodynamic data. This estimate has correlation with measured inferior caval vein saturations and offers prognostic utility.

10.
Saudi Dent J ; 36(2): 262-269, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38419999

RESUMO

Background and Objective: Although medical pulse oximeters are considered effective for endodontic diagnoses, the method remains uncommon in current dental practice. The aim of the present scoping review was to investigate clinical factors that exert a negative impact on the use of pulse oximeters in dental practice. Methods: This study followed the PRISMA-ScR guidelines and the protocol was prospectively registered in the Open Science Framework (https://doi.org/10.17605/OSF.IO/3GQCE). A comprehensive search of the MEDLINE (via PubMed), Cochrane Library, and Web of Science databases was performed in December 2022 for articles published in English or Spanish. All types of clinical studies were included, except comments, letters to the editor, and abstracts. Two independent investigators analyzed 45 full-text articles. Data extraction included general characteristics, oxygen saturation levels, and limiting factors/barriers to the use of oximeters as pulp testers. Results: The search of the databases yielded 1,300 records and 38 were included (quantitative data extraction was performed for 35 and three articles were systematic reviews). Publications were highest in number between 2016 and 2017, with an evident reduction occurring after 2021. The oxygen saturation level for sound/vital maxillary anterior teeth was 84.99% (overall mean). The main limiting factors/barriers were i) the difficulty in maintaining the two light-emitting diodes parallel during pulp tests, ii) infrared light diffraction by enamel/dentin/gingiva, and iii) the diversity of patient ages in studies. Conclusion: This scoping review encountered noteworthy findings associated with the impracticability of using medical pulse oximeters as dental pulp testers. The recent decrease in the frequency of published studies compared to approximately seven years ago may imply a negative trend in the use of the method.

11.
J Pers Med ; 14(2)2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38392600

RESUMO

Carbon monoxide (CO) poisoning is difficult to diagnose owing to its nonspecific symptoms. Multiwave pulse oximetry can be used to quickly screen patients for CO poisoning. However, few studies have analyzed patients with CO poisoning who presented to the emergency department (ED). The primary aim of our study was to determine the correlation between COHb levels measured in blood gas analysis and COHb levels measured in multiwave pulse oximetry. Secondary aims were the sensitivity and specificity of the COHb level cutoff value using multiwave pulse oximetry to predict a 25% COHb level in blood gas analysis. This single-center retrospective observational study included patients with CO poisoning who visited the ED of a university-affiliated hospital in Seoul, Korea between July 2021 and June 2023. COHb poisoning was determined using blood gas analysis and multiwave pulse oximetry. The correlation of COHb levels between the two tests was evaluated using correlation analysis. The area under the receiver operating characteristic curve (AUC) of multiwave pulse oximetry was calculated to predict COHb levels from the blood gas analysis. The optimal cutoff values, sensitivity, and specificity of COHb were determined. A total of 224 patients who had COHb levels measured using both multiwave pulse oximetry and blood gas analysis were included in the analysis. In the correlation analysis, COHb showed a high positive correlation with COHb measured using blood gas analysis (Spearman correlation coefficient = 0.86, p < 0.001). The AUC of COHb measured by multiwave pulse oximetry to predict 25% of the COHb level (which can be an indication of hyperbaric oxygen treatment) measured by blood gas analysis was 0.916. When the COHb levels measured with multiwave pulse oximetry were 20% the sensitivity was 81% and the specificity was 83%, and when the COHb levels were 25% the sensitivity was 50% and the specificity was 95%. The COHb value measured using multiwave pulse oximetry blood gas analysis showed a high correlation. However, additional research using large-scale studies is required for validation.

12.
J Clin Anesth ; 94: 111374, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38184918

RESUMO

OBJECTIVE: The current standards of postoperative respiratory monitoring on medical-surgical floors involve spot-pulse oximetry checks every 4-8 h, which can miss the opportunity to detect prolonged hypoxia and acute hypercapnia. Continuous respiratory monitoring can recognize acute respiratory depression episodes; however, the existing evidence is limited. We sought to review the current evidence on the effectiveness of continuous pulse oximetry (CPOX) with and without capnography versus routine monitoring and their effectiveness for detecting postoperative respiratory failure, opioid-induced respiratory depression, and preventing downstream adverse events. METHODS: We performed a systematic literature search on Ovid Medline, Embase, and Cochrane Library databases for articles published between 1990 and April 2023. The study protocol was registered in Prospero (ID: 439467), and PRISMA guidelines were followed. The NIH quality assessment tool was used to assess the quality of the studies. Pooled analysis was conducted using the software R version 4.1.1 and the package meta. The stability of the results was assessed using sensitivity analysis. DESIGN: Systematic Review and Meta-Analysis. SETTING: Postoperative recovery area. PATIENTS: 56,538 patients, ASA class II to IV, non-invasive respiratory monitoring, and post-operative respiratory depression. INTERVENTIONS: Continuous pulse oximetry with or without capnography versus routine monitoring. MEASUREMENTS: Respiratory rate, oxygen saturation, adverse events, and rescue events. RESULTS: 23 studies (17 examined CPOX without capnography and 5 examined CPOX with capnography) were included in this systematic review. CPOX was better at recognizing desaturation (SpO2 < 90%) OR: 11.94 (95% CI: 6.85, 20.82; p < 0.01) compared to standard monitoring. No significant differences were reported for ICU transfer, reintubation, and non-invasive ventilation between the two groups. CONCLUSIONS: Oxygen desaturation was the only outcome better detected with CPOX in postoperative patients in hospital wards. These comparisons were limited by the small number of studies that could be pooled for each outcome and the heterogeneity between the studies.


Assuntos
Analgésicos Opioides , Insuficiência Respiratória , Humanos , Analgésicos Opioides/efeitos adversos , Taxa Respiratória , Capnografia/métodos , Monitorização Fisiológica/métodos , Insuficiência Respiratória/induzido quimicamente , Insuficiência Respiratória/prevenção & controle , Insuficiência Respiratória/diagnóstico , Oximetria/métodos , Complicações Pós-Operatórias/diagnóstico , Hospitais
13.
J Clin Monit Comput ; 38(2): 347-354, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38238634

RESUMO

PURPOSE:  Evaluate the SpO2-SaO2 difference between Black and White volunteer subjects having a low perfusion index (Pi) compared to those having a normal Pi. METHODS:  The Pi data were abstracted from electronic files collected on 7183 paired SpO2-SaO2 samples (3201 Black and 3982 White) from a recently reported desaturation study of 75 subjects (39 Black and 36 White) where SaO2 values were sequentially decreased from 100 to 70%. The Pi values from that dataset were divided into two groups (Pi ≤ 1 or Pi > 1) for analysis. A Pi value ≤ 1 was considered "low perfusion" and a Pi value > 1 was considered "normal perfusion". Statistical calculations included values of bias (mean difference of SpO2-SaO2), precision (standard deviation of the difference), and accuracy (root-mean-square error [ARMS]). During conditions of low perfusion (Pi ≤ 1, range [0.1 to 1]), overall bias and precision were + 0.48% ± 1.59%, while bias and precision were + 0.19 ± 1.53%, and + 0.91 ± 1.57%, for Black and White subjects, respectively. RESULTS:  During normal perfusion (Pi > 1, range [1 to 12]), overall bias and precision were + 0.18% ± 1.34%, while bias and precision were -0.26 ± 1.37%, and - 0.12 ± 1.31%, for Black and White subjects, respectively. ARMS was 1.37% in all subjects with normal perfusion and 1.64% in all subjects with low perfusion. CONCLUSION:  Masimo SET® pulse oximeters with RD SET® sensors are accurate for individuals of both Black and White races when Pi is normal, as well as during conditions when Pi is low. The ARMS for all conditions studied is well within FDA standards. This study was conducted in healthy volunteers during well-controlled laboratory desaturations, and results could vary under certain challenging clinical conditions.


Assuntos
Oximetria , Índice de Perfusão , Humanos , Reprodutibilidade dos Testes , Oximetria/métodos , Oxigênio , Gasometria , Hipóxia
14.
Crit Care Nurs Clin North Am ; 36(1): 99-110, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38296378

RESUMO

Pulse oximetry screening (POS) was first described over 20 years ago. However, in recent years, major clinical trials have demonstrated consistent test accuracy for the detection of critical congenital heart defects (CCHD). International uptake of POS has progressed well over the last 10 years with most major high-income countries now recommending screening. This review describes the evidence base which has led to this, the current debate regarding choice of screening algorithm, and the future areas for further research.


Assuntos
Cardiopatias Congênitas , Recém-Nascido , Lactente , Humanos , Cardiopatias Congênitas/diagnóstico , Oximetria , Algoritmos
15.
World J Emerg Med ; 15(1): 16-22, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38188554

RESUMO

BACKGROUND: Unsustained return of spontaneous circulation (ROSC) is a critical barrier to survival in cardiac arrest patients. This study examined whether end-tidal carbon dioxide (ETCO2) and pulse oximetry photoplethysmogram (POP) parameters can be used to identify unsustained ROSC. METHODS: We conducted a multicenter observational prospective cohort study of consecutive patients with cardiac arrest from 2013 to 2014. Patients' general information, ETCO2, and POP parameters were collected and statistically analyzed. RESULTS: The included 105 ROSC episodes (from 80 cardiac arrest patients) comprised 51 sustained ROSC episodes and 54 unsustained ROSC episodes. The 24-hour survival rate was significantly higher in the sustained ROSC group than in the unsustained ROSC group (29.2% vs. 9.4%, P<0.05). The logistic regression analysis showed that the difference between after and before ROSC in ETCO2 (ΔETCO2) and the difference between after and before ROCS in area under the curve of POP (ΔAUCp) were independently associated with sustained ROSC (odds ratio [OR]=0.931, 95% confidence interval [95% CI] 0.881-0.984, P=0.011 and OR=0.998, 95% CI 0.997-0.999, P<0.001). The area under the receiver operating characteristic curve of ΔETCO2, ΔAUCp, and the combination of both to predict unsustained ROSC were 0.752 (95% CI 0.660-0.844), 0.883 (95% CI 0.818-0.948), and 0.902 (95% CI 0.842-0.962), respectively. CONCLUSION: Patients with unsustained ROSC have a poor prognosis. The combination of ΔETCO2 and ΔAUCp showed significant predictive value for unsustained ROSC.

16.
Vet Sci ; 11(1)2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38250933

RESUMO

This study aimed to investigate the association of respiratory rate (RR), oxygen saturation (SpO2), and blood findings with respiratory disease in dogs and to compare the examination findings in the chronic and acute phases. Dogs that visited a veterinary referral hospital with respiratory symptoms were classified into the chronic disease group (GC), and those that visited the emergency veterinary hospital were classified into the acute disease group (GA). In total, 704 and 682 dogs were included in GC and GA, respectively. The RR and SpO2 were significantly higher and lower, respectively, in patients with lung disease compared to other disease sites in both groups. White blood cell counts were significantly increased in patients with lung and pleural diseases in both groups. Respiratory alkalosis and respiratory acidosis were most common in GC and GA, respectively. The C-reactive protein levels were elevated in both groups, primarily in patients with lung disease. Associations between the results of several tests for understanding and diagnosing respiratory conditions and diseases were recognized, and differences in the trends of the chronic and acute phases were clarified. These tools may be used as adjuncts to other tests for the diagnosis and monitoring of treatment responses.

17.
Sensors (Basel) ; 24(2)2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38257528

RESUMO

Blood oxygen saturation (SpO2) is an essential indicator of a patient's general condition. However, conventional measurement methods have some issues such as time delay and interference by ambient light. Improved measurement methods must be developed, and there are no reports on intraoral measurements of SpO2 using wearable devices. Therefore, we aimed to establish an intraoral SpO2 measurement method for the first time. Twelve healthy adults participated in this study. The following steps were taken: (1) to identify the optimal measurement location, mid-perfusion index (PI) values were measured at six places on the mucosa of the maxilla, (2) to validate the optimal measurement pressure, PI values were obtained at different pressures, and (3) using the proposed mouthpiece device, SpO2 values in the oral cavity and on the finger were analyzed during breath-holding. The highest PI values were observed in the palatal gingiva of the maxillary canine teeth, with high PI values at pressures ranging from 0.3 to 0.8 N. In addition, changes in SpO2 were detected approximately 7 s faster in the oral cavity than those on the finger, which is attributed to their proximity to the heart. This study demonstrates the advantage of the oral cavity for acquiring biological information using a novel device.


Assuntos
Dedos , Boca , Adulto , Humanos , Extremidade Superior , Suspensão da Respiração , Gengiva
18.
Pediatr Blood Cancer ; 71(4): e30879, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38279845

RESUMO

BACKGROUND: Adequate oxygen saturation (SpO2 ) is crucial for managing sickle cell disease (SCD). Children with SCD are at increased risk for occult hypoxemia; therefore, understanding SpO2 threshold practices would help identify barriers to oxygen optimization in a population sensitive to oxyhemoglobin imbalances. We investigated SpO2 cutoff levels used in clinical algorithms for management of acute SCD events at children's hospitals across the United States, and determined their consistency with recommended national guidelines (SpO2  > 95%). METHODS: Clinical pathways and algorithms used for the management of vaso-occlusive crisis (VOC) and acute chest syndrome (ACS) in SCD were obtained and reviewed from large children's hospitals in the United States. RESULTS: Responses were obtained from 94% (140/149) of eligible children's hospitals. Of these, 63 (45%) had available clinical algorithms to manage VOC and ACS. SpO2 cutoff was provided in 71.4% (45/63) of clinical algorithms. Substantial variation in SpO2 cutoff levels was noted, ranging from ≥90% to more than 95%. Only seven hospitals (5% of total hospitals and 15.6% of hospitals with clinical algorithms available) specified oxygen cutoffs that were consistent with national guidelines. Hospitals geographically located in the South (46.8%; n = 29/62) and Midwest (54.8%; n = 17/31) were more likely to have VOC and ACS clinical algorithms, compared to the Northeast (26.5%; n = 9/34) and West (36.4%; n = 8/22). CONCLUSION: There is inconsistency in the use of clinical algorithms and oxygen thresholds for VOC and ACS across US children's hospitals. Children with SCD could be at risk for insufficient oxygen therapy during adverse acute events.


Assuntos
Síndrome Torácica Aguda , Anemia Falciforme , Compostos Orgânicos Voláteis , Criança , Humanos , Estados Unidos , Saturação de Oxigênio , Anemia Falciforme/terapia , Anemia Falciforme/complicações , Síndrome Torácica Aguda/etiologia , Síndrome Torácica Aguda/terapia , Oxigênio , Hospitais
19.
Adv Mater ; 36(9): e2310478, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38054854

RESUMO

White-light detection from the visible to the near-infrared region is central to many applications such as high-speed cameras, autonomous vehicles, and wearable electronics. While organic photodetectors (OPDs) are being developed for such applications, several challenges must be overcome to produce scalable high-detectivity OPDs. This includes issues associated with low responsivity, narrow absorption range, and environmentally friendly device fabrication. Here, an OPD system processed from 2-methyltetrahydrofuran (2-MeTHF) sets a record in light detectivity, which is also comparable with commercially available silicon-based photodiodes is reported. The newly designed OPD is employed in wearable devices to monitor heart rate and blood oxygen saturation using a flexible OPD-based finger pulse oximeter. In achieving this, a framework for a detailed understanding of the structure-processing-property relationship in these OPDs is also developed. The bulk heterojunction (BHJ) thin films processed from 2-MeTHF are characterized at different length scales with advanced techniques. The BHJ morphology exhibits optimal intermixing and phase separation of donor and acceptor moieties, which facilitates the charge generation and collection process. Benefitting from high charge carrier mobilities and a low shunt leakage current, the newly developed OPD exhibits a specific detectivity of above 1012  Jones over 400-900 nm, which is higher than those of reference devices processed from chlorobenzene and ortho-xylene.

20.
J Clin Monit Comput ; 38(1): 113-120, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37882880

RESUMO

PURPOSE: Recent reports that pulse oximeters may overestimate oxygen saturation in individuals with darker skin pigmentation have prompted concerns from regulatory authorities regarding racial bias. We investigated the performance of TruSignal SpO2 sensors (GE Healthcare, Helsinki, Finland) in adults with varying skin pigmentation. METHODS: A retrospective study was conducted using a set of pooled assessments of SpO2/SaO2 measurements from nine studies to assess bias, accuracy (Arms), and precision of TruSignal sensors in healthy adults under induced hypoxia. Subgroup analyses were performed based on oxygen saturation levels (band 1, ≥ 70 and ≤ 80%; band 2, > 80 and ≤ 90%; band 3, > 90 and ≤ 100%). RESULTS: Of the 10,800 data points from 131 individuals, 8,202 (75.9%) and 2,598 (24.1%) were assigned to the light and dark pigment groups, respectively. Bias was 0.14% overall and less than 1% across oxygenation bands. The difference in bias between dark and light pigment groups was statistically significant at the low oxygenation band with SpO2 ≥ 70 and ≤ 80% (+ 0.58% and + 0.30% respectively; p = 0.0035). Throughout the saturation range, Arms was 1.64% in the light and 1.71% in the dark pigment group, within device specifications and regulatory requirements. Oxygenation was the dominating factor in stepwise ANOVA modeling. The mixed model also showed that bias was strongly affected by the oxygenation range. CONCLUSION: TruSignal sensors demonstrated higher bias at lower oxygen saturation, with less than 0.5% difference between pigment groups. These findings raise new questions, such as ways to improve pulse oximetry measurements during challenging clinical conditions, including low perfusion.


Assuntos
Oximetria , Pigmentação da Pele , Adulto , Humanos , Estudos Retrospectivos , Oxigênio , Hipóxia/diagnóstico